Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis
2007
Background— Percutaneous aortic valve replacement represents an endovascular alternative to conventional open heart surgery without the need for sternotomy, aortotomy, or cardiopulmonary bypass. Methods and Results— Transcatheter implantation of a balloon-expandable stent valve using a femoral arterial approach was attempted in 50 symptomatic patients with severe aortic stenosis in whom there was a consensus that the risks of conventional open heart surgery were very high. Valve implantation was successful in 86% of patients. Intraprocedural mortality was 2%. Discharge home occurred at a median of 5 days (interquartile range, 4 to 13). Mortality at 30 days was 12% in patients in whom the logistic European System for Cardiac Operative Risk Evaluation risk score was 28%. With experience, procedural success increased from 76% in the first 25 patients to 96% in the second 25 (P=0.10), and 30-day mortality fell from 16% to 8% (P=0.67). Successful valve replacement was associated with an increase in echocardiog...
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
40
References
1001
Citations
NaN
KQI