pH and Conductivity Calculations and Measurements Relevent to the pbar Target Station

1992 
During the most recent collection lens failure, it is believed that the conductivity measurement system failed. Evidence that the septum failed and released lithium into the water without tripping the conductivity interlock comes from measurements of the pH of the water and the fact that the pressure in the closed loop water system nearly doubled in twenty minutes. The interlock sum tripped on overpressure and approximately 1 liter of water was released from the relief valve. Given this set of circumstances, it seems prudent to calculate the expected lithium release into the water and the corresponding expected conductivity for the pH measured.