Surgical Treatment of a Catheter-Induced Iatrogenic Dissection of the Right Coronary Artery following Cardiac Catheterization

2016 
Iatrogenic dissections of the ascending aorta are an uncommon and severe complication during cardiac catheterization. A 68-year-old female patient underwent diagnostic cardiac catheterization due to non-ST-elevation myocardial infarction. During the procedure, a catheter-induced 360° Class I dissection of the right coronary artery occurred. The patient developed severe bradycardia, which was treated with a temporary pacemaker. She underwent an emergency operation with ligation and a saphenous vein graft in the right coronary artery. The postoperative course was uneventful; and on postoperative day 6, she was discharged home.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader