Overvoltage protection by point-plane spark gaps

1979 
In electron-beam-controlled discharge CO/sup 2/ lasers, such as those used in the Antares and Helios laser-fusion drivers at the Los Alamos Scientific Laboratory (LASL), protection needs to be provided against possible damage due to overvoltage. A passive (self-breakdown) point-plane spark gap has been developed and successfully used in the Helios power amplifiers which operate at voltages up to 300 kV. A gap of similar design is planned for use in the Antares power amplifiers which operate at 550 kV. These gaps must reliably hold off the normal discharge voltage, but break down with short delay if overvoltaged, diverting the discharge energy to a resistor. A prototype of the Antares gap has been built and is undergoing tests. Parameters being investigated include voltage polarity, gap spacing, gas composition, and gas pressure. Results of these measurements and the operational experience of the Helios gaps will be presented.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []