Nitric oxide removal from flue gas using dielectric barrier discharge coupled with negative pulse corona

2019 
Abstract To optimize the efficiency of nitric oxide (NO) removal, a new catalyst-free method at room temperature was developed by combining dielectric barrier discharge (DBD) and negative pulse corona (NPC). With this method, the effects of applied current, initial NO concentration, gas flow rate, O 2 concentration, methanol addition, and the selection of applied current and gas flow rate on NO removal were investigated respectively. Results showed that increasing current not only promoted the NO removal but also reduced NO 2 and N 2 O formation. The NO removal efficiency had a negative dependence on initial NO concentration and gas flow rate. A negative effect of O 2 on NO removal was observed, and it also promoted the formation of NO 2 . However, adding methanol was able to mitigate the negative effects and eliminate NO 2 exhaust. The addition of 0.5 vol% methanol raised NO removal efficiency from 30.9% to 98.6% under the condition of 1.67 A, 500 ppm NO, 0.625 L/min with 8 vol% O 2 in the flue gas. The reaction path of NO removal process was strongly altered as methanol added into DBD-NPC processing. NO X (NO, NO 2 ) can be reduced to N 2 with CH 3 OH as a reductant. A simple combined denitration method (DBD-NPC) without the assistance of selective catalytic reduction (SCR), additional heating and pressure was developed and evaluated, which may provide potential applications for denitration industry.