Coupling of Oxy- and Deoxyhemoglobin concentrations with EEG rhythms during motor task

2017 
A relationship between the brain rhythmic activity and the hemodynamic response was studied using the simultaneous measurement of electroencephalogram (EEG) and the functional near-infrared spectroscopy (fNIRS) during a motor task (self-paced right finger movements) for 10 subjects. An EEG recording with a 32-electrode (10-10) system was made and the hemodynamic response was obtained using 8 optodes placed over the sensorimotor cortex on both hemispheres. During the task an increase in oxyhemoglobine (HbO) was accompanied by a decrease in deoxyhemoglobine (HbR) concentration and a decrease in amplitudes (desynchronisation) of alpha (8–13 Hz) and beta (13–30 Hz) EEG rhythms. These phenomena were prominent in the hemisphere contralateral to the moving finger. The delays between the hemodynamic and electrophysiological variables were on average 2.8 s. Highly significant (p < 0.0001) negative Pearson correlations were found between HbO and alpha (r2 = −0.69) and HbO and beta (r2 = −0.54) rhythms. Positive correlations r2 = 0.5 between these rhythms and HbR were found.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    32
    References
    16
    Citations
    NaN
    KQI
    []