An Active-Distributed Temperature Sensing method to quantifygroundwater – surface water exchanges
2017
Understanding and quantifying groundwater and surface water interactions are key elements for the management
of water quality and quantity, but also for the preservation of groundwater dependent ecosystems and riparian
habitat. We developed a methodology to quantify groundwater and surface water interactions, by setting up an
active heat tracer experiment using fiber-optic distributed temperature sensing (FO-DTS).
The experimental setup consists in heating an armoured fiber-optic cable that has been previously deployed
along the streambed within the sediments. Then, the increase in temperature along the heated cable is a function
of the thermal properties of the sediments and of the fluid flow velocity within the sediments. The cable is
heated electrically through the steel armouring of the cable while the elevations in temperature are continuously
monitored. We tested this methodology on the Kerbernez catchment, located in south-western Brittany (France)
and which is part of the AgrHys hydrological observatory. We deploy the cable in a first-order stream within this
small agricultural catchment (0.12 km
2
). Temperature was monitored along 60 meters of stream with a spatial and
temporal resolution respectively equal to 29 cm and 30 s. To interpret the data, we used an analytical solution
developed for geothermal energy that considers advection and conduction of temperature in porous media. To
validate the use of the analytical solution and to define the limits of the method, a 2D numerical model has been
developed. This model simulates heat transport and conduction with steady state fluid flow using the Conjugate
Heat Transfer module of COMSOL Multiphysics
®
.
During heating and cooling, the measured temperature was particularly variable along the section with
temperature increases that range between 16 to 36
C. This variability can directly be associated with local
variations of water fluxes by applying the appropriate analytical solution. Henceforth, it is possible to model
field data, just by adjusting one free parameter: the flow velocity within the sediments. For the electrical power
used, these preliminary tests permits to estimate fluxes between groundwater and surface water between 8.10
^
-7
to 6.10
^
-5 m.s-1. Thus, our results show that an active heat tracer experiment using fiber-optic distributed tem-
perature sensing can be a promising and innovative method to quantify surface water and groundwater interactions
Keywords: