BEAM SIMULATION OF SQQ INJECTION SYSTEM IN KIRAMS-30 CYCLOTRON ∗

2006 
The injection system of KIRAMS-30 cyclotron consists of a doublegap buncher,an SQQ, and a spiral inflector. Initial beam with 100 mmmrad has been generated by random Gaussian function in the transverse plane and random uniform function in the longitudinal direction. Using the 3D electric and magnetic fields of a buncher, SQQ, inflector, and return-yoke bore, the characteristics of the beam injected into the KIRAMS-30 cyclotron’s central region has been obtained. This paper presents the results of its beam characteristics and parameters of each beam element.