Determination of antimony compounds in waters and juices using ion chromatography-inductively coupled plasma mass spectrometry

2017 
Abstract A method was developed by coupling ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) for the speciation of antimony. In this study, antimony species such as antimonite [Sb(III)], antimonate [Sb(V)] and trimethyl antimony(V) (TMeSb) were separated in less than 8 min using anion exchange chromatography with a Hamilton PRP-X100 column as the stationary phase. Mobile phase A was 20 mmol L −1 ethylenediaminetetraacetic acid (EDTA), 2 mmol L −1 potassium hydrogen phthalate (KHP) in 1% v/v methanol (pH 5.5) and 20 mmol L −1 EDTA, 2 mmol L −1 KHP, 40 mmol L −1 (NH 4 ) 2 CO 3 in 1% v/v methanol (pH 9.0) formed mobile phase B. Detection limits and relative standard deviations (RSD) were 0.012–0.032 ng mL −1 and 2.2–2.8% respectively. This method was applied to bottled waters and fruit juices purchased in Kaohsiung, Taiwan. In water samples, Sb(V) was the major species where as in juices organometallic Sb species were also present.