Evaluating Alternative Materials for the Treatment of Stress Urinary Incontinence and Pelvic Organ Prolapse: A Comparison of the In Vivo Response to Meshes Implanted in Rabbits
2016
Purpose: Serious complications can develop with the mesh implants used for stress urinary incontinence and pelvic organ prolapse surgery. We evaluated 2 materials currently in clinical use and 2 alternative materials using a rabbit abdominal model to assess host response and biomechanical properties of the materials before and after implantation.Materials and Methods: Poly-L-lactic acid and polyurethane meshes were electrospun to be compared to commercially available polypropylene and polyvinylidene fluoride meshes. A total of 40 immunocompetent full-thickness abdominal wall defect rabbit models were used, including 8 in each of the poly-L-lactic acid, polyurethane, polyvinylidene fluoride and polypropylene experimental groups, and sham controls. Two 20 mm defects were created per animal and primarily repaired. The experimental groups then underwent onlay of each repair material while sham controls did not. Four rabbits per group were sacrificed at days 30 and 90. Abdominal wall specimens containing the d...