Double ROI Timing Bolus Technique to Perform Aortic CT Angiography With a 9-Second Contrast Injection Duration

2019 
OBJECTIVE. The purpose of this study was to investigate the feasibility of a double ROI timing bolus technique for performing aortic CT angiography (CTA) with 40 mL of contrast medium over 9 seconds. SUBJECTS AND METHODS. A prospective study from February to July 2018 included 106 patients with clinical indications for evaluation of aortic aneurysm or dissection or suspected aortic disease. Forty-seven of these patients had undergone prior aortic CTA by the conventional method. The scanning speed for the double ROI timing bolus technique was calculated from the time-attenuation curves of the ascending and descending aorta by use of the timing bolus data to synchronize aortic flow. The conventional scan was obtained by injection of 1.7 mL of contrast medium per kilogram of body weight for 25 seconds. Enhancement of six points on the aortoiliac arteries and superior vena cava was measured. The t test was used to compare the values. RESULTS. Use of the double ROI timing bolus method significantly reduced the...