An institutional retrospective study of coil loop herniation and its management
2019
Introduction: Endovascular coiling is a method of aneurysm embolization. Sometimes coil loops herniate in the lumen after deployment of the coil. It is usually seen in wide-necked aneurysms. It can cause migration of the coil and thromboembolic complications. There are different methods such as the use of a balloon, stent, and coil retriever to treat coil loop herniation. There are very few case series on coil loop herniation management. Most series are about the use of a stent/balloon for reposition. We are going to describe simple, novel techniques to treat coil loop herniation.
Materials and Methods: In the last five years, 13 aneurysms out of 325 coiled aneurysms had coil loop herniation. We used three different techniques in these patients according to our selection criteria. The first technique was loop trap with another coil, the second was balloon and coil-plasty to trap, and the third was rescue stent and flow control.
Results: The first, second, and third techniques were successfully used in five, five and three patients, respectively. There was a complete reposition of herniated coil and thus embolization of aneurysm in all cases. All patients recovered completely without any thromboembolic complications.
Conclusions: We recommend the use of these techniques according to the proper selection criteria.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
0
References
0
Citations
NaN
KQI