A Unified Total Site Heat Integration targeting method for isothermal and non-isothermal utilities

2017 
This paper presents a new unified Total Site Heat Integration (TSHI) targeting methodology that calculates improved TSHI targets for sites that requires isothermal (e.g. steam) and non-isothermal (e.g. hot water) utilities. The new method sums process level utility targets to form the basis of Total Site utility targets; whereas the conventional method uses Total Site Profiles based excess process heat deficits/surpluses to set Total Site targets. Using an improved targeting algorithm, the new method requires a utility to be supplied to and returned from each process at specified temperatures, which is critical when targeting non-isothermal utilities. Such a constraint is not inherent in the conventional method. The subtle changes in procedure from the conventional method means TSHI targets are generally lower but more realistic to achieve. Three industrial case studies representing a wide variety of processing industries, are targeted using the conventional and new TSHI methods, from which key learnings are found. In summary, the over-estimation of TSHI targets for the three case studies from using the conventional method compared to new method are 69% for a New Zealand Dairy Factory, 8% for the Sodra Cell Varo Kraft Pulp Mill, and 12% for Petrochemical Complex.