Experimental analysis of cross-laminated timber rib panels at normal temperature and in fire

2021 
Abstract The results of an experimental programme on the structural behaviour, fire behaviour, and fire resistance of CLT rib panels are presented. The floor system consists of cross-laminated timber (CLT) plates rigidly bonded to glued-laminated timber ribs by means of screw-press gluing. The experimental programme comprised ultimate-load tests at normal temperature as reference tests and full-scale fire resistance tests on four cross-sections. In addition to the reference tests, shear tests of the glue line between CLT plate and glued-laminated timber rib were performed for analysis of the cross-sections’ composite action. The results of the reference tests show good agreement with results based on the simplified method according to EN 1995-1-1 [1] and its final draft of CLT design [2] . The importance of the glue line’s quality was confirmed. The fire resistance tests show results on the safe side compared to predictions of the fire behaviour according to EN 1995-1-2 [3] and its actual draft [4] . However, the fire resistance was underestimated due to conservative assumptions about the composite cross-section’s structural behaviour. The experimental programme addressed the fire behaviour and fire resistance of CLT rib panels currently not covered in standards. The project’s overall aim is the development of design rules in fire for EN 1995-1-2.