Dewatering and disinfection of aerobic and anaerobic sludge using an electrokinetic (EK) system

2008 
The objectives of the study were to upgrade sewage sludge to Class A Exceptional Quality biosolids (as defined by US EPA) using an electrokinetics dewatering system. The pathogens monitored were Salmonella spp, and fecal coliforms (FC). Ten bench-scale electrokinetic cells were set up for the disinfection of the following sludges: primary, secondary (attached growth culture and suspended culture), and anaerobically digested sludge. A conditioning liquid was also added to five cells. Blower system to aid in dewatering and drying was used in in four EK cells. Sludge characteristics such as water content, volatile solids content, sulfate and chloride ions concentrations, FC and Salmonella spp. before and after the tests were monitored. The highest total solids content (98% TS) was achieved in the cell with the low voltage gradient, in the presence of the conditioner and with the blower system. An average reduction by 50% of volatile solids was observed. The highest, 11 log-reduction of Salmonella spp. was observed in a cell with anaerobically digested sludge. No fecal coliforms were observed in any of the cells after EK treatment.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    12
    References
    23
    Citations
    NaN