An Experimental Study on the Fire Behavior of Concrete Void Slab under Standard Fire with Loading Condition

2011 
The concrete void slab structure with the existing mushroom slab, is the structure that maximizes the advantages, while minimizing the weakness with removing useless body force of the concrete part, located on the center of the slab cross-section, which does not need to support the structural weight. In this research, a fire test is performed to analyze how the blaze behave according to the thickness of slab cover, with the practical span length of concrete void slab for the slab length 7.5 m. With this heating test, we assumed the uniform-load-model considering fixed loads and live loads, and chose the standard fire test condition. We measured the temperature changes and the deflection character according to the depth from the heat exposure side, and assessed the resisting capability according to the standard KS F 2257-1. The result comes out with the EPS model can secure about 2 hour fire-resisting-capability with 50 mm of cover depth.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    1
    Citations
    NaN
    KQI
    []