Multisite Comparison of Mucociliary and Cough Clearance Measures Using Standardized Methods

2013 
Abstract Background: A standardized protocol for measuring mucociliary (MCC) and cough clearance (CC) was developed and tested at the University of North Carolina at Chapel Hill, NC (UNC), Johns Hopkins University (JHU), and the University of Pittsburgh (Pitt). Methods: A total of 50 healthy nonsmoking adults with normal lung function were studied at the three sites: 30 [21 males/9 females (21M/9F)] at UNC, 10 (6M/4F) at JHU, and 10 (4M/6F) at Pitt. Subjects inhaled an aerosol of 99mtechnetium sulfur colloid in 0.9% saline (mass median aerodynamic diameter=5.4 μm) under controlled breathing conditions (500 mL/sec, 30 breaths/min) by following a metronome and flow signal from a commercial dosimeter. Following inhalation, subjects sat in front of a gamma camera as sequential lung images were acquired for 60 min. Subjects then coughed 60 times, and images were acquired after each set of 20 coughs, i.e., at 70, 80, and 90 min. Subjects returned to the laboratory approximately 24 hr later for a final image of ...