Improved Preservation of Warm Ischemic Livers by Hypothermic Machine Perfusion with Supplemented University of Wisconsin Solution

2008 
Hypothermic machine perfusion (HMP) has the potential to improve recovery and preservation of Donation after Cardiac Death (DCD) livers, including uncontrolled DCD livers. However, current perfusion solutions lack the needed substrates to improve energy recovery and minimize hepatic injury, if warm ischemic time (WIT) is extended. This proof-of-concept study tested the hypothesis that the University of Wisconsin (UW) solution supplemented with anaplerotic substrates, calcium chloride, thromboxane A2 inhibitor, and antioxidants could improve HMP preservation and minimize reperfusion injury of warm ischemic livers. Preflushed rat livers subjected to 60 min WIT were preserved for 5 h with standard UW or supplemented UW (SUW) solution. Post preservation hepatic functions and viability were assessed during isolated perfusion with Krebs–Henseleit solution. Livers preserved with SUW showed significantly (p <. 001) improved recovery of tissue ATP levels (μ mol/g liver), 2.06 ± 0.10 (mean ± SE), as compared to the...