Use of Preprocedural MDCT for Cardiac Implantable Electric Device Lead Extraction: Frequency of Findings That Change Management

2017 
OBJECTIVE. Five percent of cardiac implantable electric devices (CIEDs) are removed each year. Percutaneous extraction is preferred but can be complicated if the leads adhere to the vasculature or perforate. The goal of this study is to assess the frequency of findings on dedicated MDCT that alter preprocedural planning for percutaneous CIED extraction. MATERIALS AND METHODS. One hundred patients with CIEDs who underwent MDCT before percutaneous lead extraction were analyzed. Major findings that could preclude percutaneous removal, including lead course and termination, were distinguished from moderately significant findings that could alter but not preclude percutaneous removal, including endofibrosis of leads to the vasculature, lead termination abnormalities, central vein stenosis, or thrombus. Incidental findings were characterized separately. Findings were correlated with preprocedural decisions, the extraction procedure performed, and procedural outcomes. RESULTS. Twenty-six women and 74 men with 12...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    14
    References
    12
    Citations
    NaN
    KQI
    []