After a major coil insulation breakdown on two of the 47-year-old CERN PS main magnets in 2003, an extensive magnet consolidation program has been launched. This article reviews the analysis of the magnet state before the repair and the applied major improvements. An overview is given of the production of the new components, the actual refurbishment and the commissioning of the main magnet system after 18 months shut down.