Microwave Impedance Matching of A 2.45 GHz ECR Ion Source

2013 
Plasma impedance of an ECR ion source is important for microwave transmission and impedance matching design. Plasma impedance was measured indirectly with the 2.45 GHz ECR proton source at the Institute of Modern Physics, Chinese Academy of Sciences. In the test, we got microwave window impedance by using water absorption load instead of plasma load, and the source plasma impedance was derived from the test data with the 2.45 GHz ECR proton source and microwave window impedance. The experimental results show that ridge waveguide output impedance and the subsequent load does not exactly match, plasma impedance variation is nonlinear with microwave power. The achieved result is useful in the design of ridged waveguide and microwave window.