Impulse Voltage Performance ofIce-Covered PostInsulators

2005 
Inthis paper arepresented theresults oflaboratory investigations ontheinfluence ofatmospheric icing onthe flashover performance ofpost type insulators under lightning andswitching impulse voltages. Using the"UpandDown" method, thecritical flashover voltages (V50) ofanice-covered post insulator under both positive andnegative lightning and switching impulse voltages wereexperimentally determined in aclimate chamber attheCIGELElaboratories. Thedifference between theproperties ofanice-covered insulator under lightning andswitching impulse voltages wasanalyzed. The possible mechanism underlying this difference wasexplored. Theresults maybeuseful foramoreadequate design and selection ofinsulators forcold regions.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    1
    References
    0
    Citations
    NaN
    KQI
    []