Prediction of compressor stall for distorted and undistorted flow by use of a multistage compressor simulation on the digital computer

1975 
A simulation technique is presented for the prediction of compressor stall for axial-flow compressors for clean and distorted inlet flow. The simulation is implemented on the digital computer and uses stage stacking and lumped-volume gas dynamics. The resulting nonlinear differential equations are linearized about a steady-state operating point, and a Routh-Hurwitz stability test is performed on the linear system matrix. Parallel compressor theory is utilized to extend the technique to the distorted inlet flow problem. The method is applied to the eight-stage J85-13 compressor. Analytical stall prediction for the undistorted stall line shows good agreement with experimental results. The predicted stall line for distorted inlet flow is in agreement with experimental results only for large distortion extents and/or low distortion levels. Results for low distortion extents and high distortion level do not agree with experimental results.
    • Correction