Excessively low cholesterol and triglyceride levels in an apparently healthy patient.

2021 
Lipid panels are a commonly performed test in clinical laboratories. Due to the high prevalence of cardiovascular diseases around the world, it is common to see serum or plasma specimens with high results for one or more components of the lipid panel. Exceedingly low results, however, are rare and may be attributed to certain genetic, infectious, or autoimmune conditions in addition to analytical interference. Here we report a serum specimen from a 58-year-old female with cholesterol and triglyceride values below the detection limit of the assay, which was investigated to identify the cause of the anomaly. Using vitamin C test strips and high-performance liquid chromatography, the presence of high levels of antioxidant vitamin C in the patient specimen was confirmed. Subsequent treatment of the sample with the enzyme ascorbate oxidase inactivated vitamin C, leading to lipid analyte values falling within the expected range upon repeat analysis. Thus, analytical interference by vitamin C should be considered when suspiciously low lipid panel results are encountered.