A. Zhuravlev, A. Batrakov, A. Chernyakin, V. Kiselev, V. Konstantinov, A. Pavlenko, V. Petrov, E. Semenov, D. Senkov, BINP, Novosibirsk, 630090, Russia Abstract Magnets for injection and extraction sections of NSLS-II 3 GeV booster are designed, manufactured and tested at BINP, Russia. This report considers the details of bump and septum magnets design, their parameters and results of the inspection test at BINP. The design and electronics features of the measurement stand for these magnets are presented. Also, capabilities of specialized power supplies are listed and discussed.