Injection Shrinkage аnd Water Sorption of Some Thermoplastic Dental Materials

2019 
Objective: To evaluate the change of diameter of different injection-molded thermoplastic materials.  Material and Methods: Four thermoplastic injection-molded materials were analyzed (Bre.flex 2 nd edition, Vertex ThermoSens, Perflex Biosens and Polyan IC). A total of 432 test samples were made in the form of an "hourglass". All samples were divided into three groups: Group I (Control) - consisting of 36 test samples for each type of material, that was not exposed to artificial aging or a wet environment; Group II - consisting of 36 test samples for each type of material, that were artificially aged through dehydration; Group III - specimen were subjected to artificial aging without dehydration. The diameter of each specimen was measured with a digital caliper. Data were analysed using the Student's t-test.  Results: Regarding to shrinkage, the samples from the Bf Control group have a mean value of 1.56 mm and was observed a shrinkage of the injection-molded polyamide material within 0.25%. The comparison between the samples from Group II and Group III showed statistically significant differences (p 0.05). The comparison between Group II and Group III for Polyan IC samples shows that Group III has a higher arithmetic mean value (p<0.01).  Conclusion: Shrinkage of the polymers during the injection process is present in all materials. The thermocycling and the storage in a dry or in a wet environment of the samples results in a change of the diameter in almost every single type of material.