The value of b0 images obtained from diffusion-weighted echo planar sequences for the detection of intracranial hemorrhage compared with GRE sequence

2013 
Abstract Purpose Our aim was to evaluate the clinical utility of b0EPI images obtained from diffusion sequence for the detection of the intracranial hemorrhagic lesions, especially acute intracerebral bleeds thereby shorten the scan time particularly in the critical acute cases of stroke. Materials and methods Among all consecutive MR brain studies performed in our department last year, we retrospectively selected those who followed the following criteria: (1) clinically suspected or radiographically confirmed acute infarction or hemorrhage. (2) MRI imaging including DWI and T2∗ images. Sensitivity of hemorrhage detection, conspicuity of lesions, and diagnostic certainty were compared between the b0EPI and GRE sequences. Results There were 77 hemorrhagic lesions with a variety of pathogeneses in various locations. 76/77 (98.7%) of these lesions were hemorrhagic (hypointense) on the GRE sequences, whereas 61 (79.2%) were characterized as hemorrhagic on b0EPI images, and 16 (20.8%) were not detected. The overall difference in hemorrhage conspicuity/diagnostic certainty between GRE and b0EPI sequences was statistically significant ( P Conclusion b0EPI sequence, although shorter in acquisition time, was inferior to GRE imaging in the detection of acute and chronic intracerebral hemorrhage.