Standardization of Tc-99 by three liquid scintillation counting methods.

2014 
Abstract The NMISA participated in the international key comparison of the pure beta-emitter Technetium-99, CCRI(II)-K2.Tc-99. The comparison solution was standardized using three methods, namely the TDCR efficiency calculation method, the CIEMAT/NIST efficiency tracing method and the 4 π (LS) β – γ coincidence tracing method with Co-60 as tracer. Excellent agreement between results obtained with the three methods confirmed the applicability of the beta spectral shape given by the latest (2011) DDEP evaluation of Tc-99 decay data, rather than the earlier (2004) evaluation.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    23
    References
    3
    Citations
    NaN
    KQI
    []