Simple aspiration with balloon catheter technique (simple ABC technique) against proximal internal carotid artery occlusion in cases of cardiogenic cerebral embolism

2018 
BackgroundIn cases of acute ischemic stroke, manual aspiration of the thrombus is commonly performed with a balloon guiding catheter placed in the cervical segment of the internal carotid artery (ICA). However, most manual aspirations using a balloon guiding catheter are combined with inner catheters, as in the direct aspiration first pass technique (ADAPT). We experienced some cases of acute ischemic stroke with proximal ICA occlusion due to cardiogenic thrombus where we obtained sufficient recanalization by simple manual aspiration from inflated Optimo 9F balloon catheters (Tokai Medical Products, Japan) placed in the origin of the cervical segment of the ICA without any inner catheter or stent retriever. We perform by preference this procedure, named the simple Aspiration with Balloon Catheter (simple ABC) technique. Herein, we report two recent cases and discuss this procedure.Case presentationCase 1: An 80-year-old man with paroxysmal atrial fibrillation developed left ICA occlusion. We performed the...