A study on performance improvement of thermoelectric cooling system by a vibrating piezoelectric actuator
2012
This study investigated on improving of cooling performance of the thermoelectric cooling system by a vibrating from
the piezoelectric actuator. Experiment was carried out to investigate cooling performance of the thermoelectric cooling
system for the cases; one without the piezoelectric actuator and the other with the piezoelectric actuator. Temperature
measurement experiment and flow visualization experiment were performed to compare cooling performance for the
cases, respectively. Cooling performance of the thermoelectric cooling system was improved by the piezoelectric
actuator when the results of temperature measurement and flow visualization were compared, because forced convection
was generated by vibrating (acoustic streaming) from the piezoelectric actuator and the cold air in cooling region was
actively circulated by impulsive convection.