The effect of time and storage environment on dimensional changes of acrylic resin post patterns.
2015
Introduction : Post and core are needed to regain retentions and functions after endodontic therapies. Also, risk of cross contamination from dental prosthesis is so high. The aim of this study was to compare dimensional changes of acrylic resin patterns (ARP) in three different storing environments. Materials and methods : conventional root canal therapy was done on one first premolar tooth and the canal filled with Guttapercha. 2/3 of the filling was expelled and 30 direct APRs were prepared by Duralay. The samples were divided into 3 groups based on storing environments: water, NaOCl 5% and air. Finally dimensional changes in coronoapical length (CAL), coronal (CD) and apical diameter (AD) of APRs were measured in 7 consecutive times (immediately after polymerization, 1, 2, 4, 8, 24, 48 hours later). All the data were analyzed by Paired T-test and Duncon test using SPSS software ver.13 at significant level of 0.05. Results : After 24 hours, the ARPs, which were stored in air, contracted 0.07, 0.06 and 0.12 mm in AD, CD and CAL; the ARPs, which were stored in water, showed 0.03, 0.06 and 0.12 mm decrease in AD, CD and CAL; But the ARPs, which were stored in NaOCl 5%, showed significant expansion in AD, CD and CAL (0.03, 0.06 and 0.10 mm) (all P values < 0.01). Conclusion : It is better not to use NaOCl for disinfecting; also the best time for storing APRs is 8 hours for water and 2 hours for air environments after setting time.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
20
References
2
Citations
NaN
KQI