Finding Optimal Ablation Parameters for Multipolar Radiofrequency Ablation

2017 
Purpose. Radiofrequency ablation (RFA) for primary liver tumors and liver metastases is restricted by a limited ablation size. Multipolar RFA is a technical advancement of RFA, which is able to achieve larger ablations. The aim of this ex vivo study was to determine optimal ablation parameters for multipolar RFA depending on applicator distance and energy input. Methods. RFA was carried out ex vivo in porcine livers with three internally cooled, bipolar applicators in multipolar ablation mode. Three different applicator distances were used and five different energy inputs were examined. Ablation zones were sliced along the cross-sectional area at the largest ablation diameter, orthogonally to the applicators. These slices were digitally measured and analyzed. Results. Sixty RFA were carried out. A limited growth of ablation area was seen in all test series. This increase was dependent on ablation time, but not on applicator distance. A steady state between energy input and energy loss was not observed. A ...