UPS with PFC input stage for railway applications with improved immunity on input overvoltage and energy strikes

2021 
The main topic of this article is uninterruptible power supply (UPS) in railway applications, focusing on the power factor correction (PFC) stage of UPS and its interaction with overvoltages and energy strikes. The PFC topology used in this article is a two-phase interleaved DC/DC boost converter with diode bridge rectifier connected to the 25 kV, 50 Hz contact line via 25 kV/0.23 kV transformer. Since overvoltages and energy strikes can occur in the contact line due to thyristor locomotive commutation or self-induction, these interferences can disturb the normal operation of the PFC module and in some cases even destroy the module. A simulation model of the PFC is created, tested with simulated overvoltages, and three modifications/improvements to the existing topology are proposed.