Influence of sludge retention time and temperature on the sludge removal in a submerged membrane bioreactor: Comparative study between pure oxygen and air to supply aerobic conditions
2014
Performance of a bench-scale wastewater treatment plant, which consisted of a membrane bioreactor, was monitored daily using pure oxygen and air to supply aerobic conditions with the aim of studying the increases of the aeration and sludge removal efficiencies and the effect of the temperature. The results showed the capacity of membrane bioreactor systems for removing organic matter. The alpha-factors of the aeration were determined for six different MLSS concentrations in order to understand the system working when pure oxygen and air were used to supply aerobic conditions in the system. Aeration efficiency was increased between 30.7 and 45.9% when pure oxygen was used in the operation conditions (a hydraulic retention time of 12 h and MLSS concentrations between 4,018 and 11,192 mg/L). Sludge removal efficiency increased incrementally, from 0.2 to 1.5% when pure oxygen was used at low sludge retention time and from 1.5% to 15.4% at medium sludge retention time when temperature conditions were lower tha...