Load Line Evaluation of a 1-MV Linear Transformer Driver (LTD)

2008 
A seven cavity LTD system has been assembled and tested in a voltage adder configuration capable of producing approximately 1-MV into a 7-Omega, critically damped load. Individual cavities have been tested with a resistive load. The seven cavity adder has been tested with a large area electron beam diode. The output pulse when tested into a resistive load is that of an RLC circuit. When tested with a dynamic load impedance, the output voltages of the cavities have an added oscillation. The oscillation affects the output pulse shape but is not harmful to the cavity components.