Usefulness of the HACOR score in predicting success of CPAP in COVID-19-related hypoxemia.

2021 
Abstract Introduction In COVID-19 associated hypoxemic acute respiratory failure (ARF) without mandatory indication for urgent endotracheal intubation, a trial of CPAP may be considered. We aimed to evaluate HACOR (heart rate, acidosis, consciousness, oxygenation, respiratory rate) score performance in these patients as predictor of CPAP failure. Methods Prospective observational multicentric study (three centers in different countries), including adult patients with SARS-CoV-2 pneumonia admitted to a respiratory intermediate care unit, presenting PaO2/FiO2  Results We enrolled 128 patients, mean age 61,7 years. Mean HACOR at 1 h after starting CPAP was 3,27 ± 3,84 and mean PaO2/FiO2 was 203,30 ± 92,21 mmHg; 35 patients (27,3 %) presented CPAP failure: 29 underwent oro-tracheal intubation and 6 died due to COVID-19 (all having a do-not-intubate order). HACOR accuracy for predicting CPAP failure was 82,03 %, while PaO2/FiO2 accuracy was 81,25 %. Conclusion Although HACOR score had a good diagnostic performance in predicting CPAP failure in COVID-19-related ARF, PaO2/FiO2 has also shown to be a good predictor of failure.