Objectives. Angiography by selective catheterization is the reference standard for coronary bypass graft patency assessment but carries a risk of serious complications. We have investigated whether 16-slice multidetector spiral computed tomography (MDCT) can substitute for selective angiography. Design. Two to three years after coronary artery bypass grafting, 45 patients with a total of 156 bypasses (100 single and 28 sequential grafts) were examined with both MDCT and conventional selective angiography on the same day. The bypasses were classified as patent, stenotic or occluded. Results. The likelihood ratio for MDCT-detected occlusion was 40, reflecting a fairly high combined sensitivity and specificity. However, 24% of the distal anastomoses could not be evaluated by MDCT, mainly because of respiratory movements, artifacts due to metal clips, and small vessel dimensions. Moreover, seven out of 117 bypasses (6%) deemed evaluable by MDCT were wrongly classified by this method. Conclusions. At present, ...