Fielding the LANL Gas Cherenkov Detector (GCD-3) at the National Ignition Facility: The engineering challenges of designing, analyzing, fabricating, testing, and commissioning the next-generation GCD detector and WellDIM3.9m insertion manipulator for use at NIF

2017 
Fielding the LANL third-generation Gas Cherenkov Detector (GCD-3) at the National Ignition Facility (NIF) revealed an array of complex engineering challenges. Fielding the GCD-3 Detector in a 3.9 meter re-entrant Well on the NIF Target Chamber required the development of a specialized detector deployment system named the WellDIM3.9m Diagnostic Manipulator (WellDIM). The most stringent design requirement entailed a no-load/no-contact condition with the Well, which dictated that all seismic loads be transferred to the Target Chamber port flange. The WellDIM transports the GCD-3 into the Well at a distance of 3.9m from Target Chamber Center. The GCD-3 Detector, outfitted with additional shielding to mitigate higher NIF backgrounds, will serve as a prototype for the future, heavily shielded “Super-GCD”.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    5
    References
    1
    Citations
    NaN