Observation of the Dynamics of a Focal Spot Using a Long-Pulse Linear Induction Accelerator
2020
A diagnostic has been developed to study the focusing dynamics of a high-power electron beam on a target. The diagnostic uses a pinhole camera to observe bremsstrahlung from the converter target. A data acquisition system yields images of the beam focal spot with a frame duration of 20 ns and an almost unlimited recording duration. The focal spot dynamics of a linear induction accelerator with an energy of 1.5 MeV, a current of 1.2 kA and a pulse duration of 350 ns were studied. The focal spot was found to be disrupted within the first 100 ns of the pulse. Defocusing has a complex 3-D character. The feasibility of additional cleaning of the target using an accelerator pre-pulse was shown. Stable beam focusing for up to 200 ns was demonstrated.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
26
References
2
Citations
NaN
KQI