Impact of significant paravalvular leaks after transcatheter aortic valve implantation on anaemia and mortality.

2020 
Objective The aim of this work is to assess the relationship between significant paravalvular leak (SPL) after transcatheter aortic valve implantation (TAVI) on anaemia and their impact on prognosis. Methods Observational analytic study developed at two university hospitals, including all consecutive patients who underwent TAVI during a 10-year period (2009 to 2018). A logistic regression model was created to determine independent predictors of anaemia at 3 months. Time to event outcomes were analysed with Cox regression. Median follow-up was 21.3±21.9 months. Results 788 patients were included. 5.3% had SPL. SPL was an independent predictor of anaemia 3 months after TAVI (OR: 8.31, 95% CI: 2.06 to 33.50). SPL and anaemia at 3 months were independently associated with long-term mortality (HR: 1.82, 95% CI: 1.16 to 2.85; HR: 2.07, 95% CI: 1.39 to 3.08). Conclusion SPL is an independent predictor of anaemia at 3 months after TAVI, a condition that doubles long-term mortality. Our findings could explain in part the worse prognosis of SPL after TAVI. Further pathophysiological studies are necessary to explain this association.