Fabrication and performance of high-frequency composite transducers with triangular-pillar geometry

2009 
A single-element, 40-MHz, 3-mm diameter transducer was fabricated with a geometric focus at 9 mm. The transducer was based on a piezo-composite substrate with triangular-shaped composite pillars. The 2-way bandwidth of 50% and impedance magnitude were in agreement with that predicted using finite-element modeling. A one-way radiation pattern was collected using a needle hydrophone. The one-way -3 dB beamwidth at the geometric focus was measured to be 120 mum and the -3 dB depth of field was 2.5 mm. This is in good agreement with the theoretical predictions of 112.5 mum and 2.4 mm. The triangular-pillar composite transducer was then compared with a transducer with square composite pillars with similar volume fraction of active ceramic. A 9.5 dB reduction in the amplitude of the secondary resonance was found for the triangular-pillar composite as well as a 30% gain in the 2-way pulse bandwidth. A 256-element 30-MHz linear array was fabricated as a preliminary investigation into the use of the triangular pillar as the substrate in a high-frequency linear array transducer. In vivo images were generated with both the single-element and linear-array transducers.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    19
    References
    18
    Citations
    NaN