Regenerative Battery Charging Control Method for PMSM Drive without a DC/DC Converter

2019 
This paper illustrates regenerative battery charging control method of the permanent magnet synchronous motor (PMSM) drive without DC/DC converter. Conventional control methods for battery current and voltage control methods generally use a bidirectional DC/DC converter for regenerative control. The reason to use this DC/DC converter is the DC-Link current ripple of the inverter of is affected by switching of the inverter and the motor speed. This problem causes to use a low pass filter (LPF) for sensing the DC-link current, however, it occurs deteriorating the control performance. In this paper, battery current and voltage control methods using only the motor drive are illustrated. To control the DC-link current, power control is performed using the look-up table (LUT) data that are extracted from the experiment. In addition, an applicable method for the variable DC-link voltage of the proposed regenerative control method is illustrated.
    • Correction