A comparative study on the value of FDG-PET and sentinel node biopsy to identify occult axillary
2006
metastases. Patients and Methods: In all, 236 patients with breast cancer and clinically negative axilla were enrolled in the study. 18-FDG-PET was carried out before surgery, using a positron emission tomography (PET)/computed tomography scanner. In all patients, SNB was carried out after identification through lymphoscintigraphy. Patients underwent axillary lymph nodes dissection (ALND) in cases of positive FDG-PET or positive SNB. The results of PET scan were compared with histopathology of SNB and ALND. Results: In all, 103 out of the 236 patients (44%) had metastases in axillary nodes. Sensitivity of FDG-PET scan for detection of axillary lymph node metastases in this series was low (37%); however, specificity and positive predictive values were acceptable (96% and 88%, respectively). Conclusions: The high specificity of PET imaging indicates that patients who have a PET-positive axilla should have an ALND rather than an SNB for axillary staging. In contrast, FDG-PET showed poor sensitivity in the detection of axillary metastases, confirming the need for SNB in cases where PET is negative in the axilla.