Lack of correlation between Legionella colonization and microbial population quantification using heterotrophic plate count and adenosine triphosphate bioluminescence measurement

2015 
This investigation compared biological quantification of potable and non-potable (cooling) water samples using pour plate heterotrophic plate count (HPC) methods and adenosine triphosphate (ATP) concentration measurement using bioluminescence. The relationship between these measurements and the presence of Legionella spp. was also examined. HPC for potable and non-potable water were cultured on R2A and PCA, respectively. Results indicated a strong correlation between HPC and ATP measurements in potable water (R = 0.90, p 1000 CFU/mL) which consisted primarily of non-tuberculous mycobacteria. HPC concentrations have been suggested to be predictive of Legionella presence, although this has not been proven. Our evaluation showed that HPC or ATP demonstrated a fair predictive capacity for Legionella positivity in potable water (HPC: receiver operating characteristic (ROC) = 0.70; ATP: ROC = 0.78; p = 0.003). However, HPC or ATP correctly classified sites as positive only 64 and 62 % of the time, respectively. No correlation between HPC or ATP and Legionella colonization in non-potable water samples was found (HPC: ROC = 0.28; ATP: ROC = 0.44; p = 0.193).