A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures

2016 
Background A lateral approach with open reduction and internal fixation with a plate is a very effective technique for the majority of distal fibular fractures. However, this open approach for ankle fixation may be complicated by wound dehiscence and infection, especially in high-risk patients. An alternative to plating is an intramedullary implant, which allows maintenance of length, alignment, and rotation and which allows for decreased soft tissue dissection. While there has been clinical data suggesting favorable short-term outcomes with these implants, there is no current biomechanical literature investigating this technology in this particular fracture pattern. This study sought to biomechanically compare an emerging technology with an established method of fixation for distal fibular fractures that traditionally require an extensive exposure.