Gettering of Cu by He-induced cavities in SIMOX materials

1998 
Abstract Gettering of Cu impurities to He-implantation induced cavities in separation by implantation of oxygen (SIMOX) materials has been investigated by means of cross-sectional transmission electron microscopy and secondary ion mass spectroscopy. The cavities were introduced beneath the buried oxide layer (BOX) in SIMOX substrates by He + implantation (9×10 16 /cm 2 , 60 keV) and subsequent annealing. The results indicate that these cavities are strong gettering sites for Cu impurities which have been implanted into the top Si layer of SIMOX. After a 1000°C annealing, 80% of the initially implanted Cu impurities in the top layer have diffused through the buried oxide layer to be captured by the cavities. The gettering effect of these He-induced cavities is much stronger than the damage region beside the BOX. The buried oxide in SIMOX does not appear to prevent the movement of Cu at 1000°C. He + implantation-induced cavity has been demonstrated to be an attractive method to remove Cu impurities away from the top Si layer in SIMOX wafers.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    12
    References
    3
    Citations
    NaN
    KQI
    []