Intensity discrimination with cochlear implants

1983 
Intensity difference limens were measured for various frequencies and intensities of sinusoidal and pulsatile electrical stimulation in monkeys with electrodes implanted in the scala tympani, scala vestibuli, modiolus, or middle ear. Difference limens decreased, as a function of initial stimulus intensity, from values of 1.5–3 dB near threshold to as low as 0.5 dB near the upper limit of the dynamic range. If sensation level was held constant, difference limens decreased as a function of frequency up to about 500 Hz, and then remained constant. They were similar across a variety of electrode placements and separations if differences in threshold and dynamic range were taken into account. However, difference limens measured in severely damaged ears were slightly smaller than those in moderatly damaged ears. The near miss to Weber’s law, characteristic of acoustic difference limens, was not seen with electrical stimuli. Difference limens for electrical stimuli were roughly one‐half those for acoustic stimul...