Automatic Start-Up of UASB Reactors
2001
A control system to automate the start-up of anaerobic wastewater treatment reactors is presented. The system controls the feedflow rate, using the biogas production or the biogas flow rate as the only on-line variable. Furthermore, other off-line parameters, such as methane content in the biogas and COD of influent are also necessary to calculate the COD balance in the reactor. Two different start-up strategies were applied: fed batch and continuous operation. In the fed-batch operation the frequency of feeding is automatically set depending on the efficiency in COD removal. The residual organic load fraction (the fraction of influent COD not degraded to methane), is the key parameter enabling the controller the modification of feeding frequency. In order to improve reliability of the system, a second parameter k representing the gas flow rate, was introduced. By using this strategy, starting from an organic loading rate (OLR) lower than 0.5 kg COD/(m3⋅day), a load higher than 8 kg COD/(m3⋅day) was achie...
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
27
References
9
Citations
NaN
KQI