Dependence of intravoxel incoherent motion diffusion MR threshold b-value selection for separating perfusion and diffusion compartments and liver fibrosis diagnostic performance:

2019 
BackgroundIntravoxel incoherent motion (IVIM) tissue parameters depend on the threshold b-value.PurposeTo explore how threshold b-value impacts PF (f), Dslow (D), and Dfast (D*) values and their performance for liver fibrosis detection.Material and MethodsFifteen healthy volunteers and 33 hepatitis B patients were included. With a 1.5-T magnetic resonance (MR) scanner and respiration gating, IVIM data were acquired with ten b-values of 10, 20, 40, 60, 80, 100, 150, 200, 400, and 800 s/mm2. Signal measurement was performed on the right liver. Segmented-unconstrained analysis was used to compute IVIM parameters and six threshold b-values in the range of 40–200 s/mm2 were compared. PF, Dslow, and Dfast values were placed along the x-axis, y-axis, and z-axis, and a plane was defined to separate volunteers from patients.ResultsHigher threshold b-values were associated with higher PF measurement; while lower threshold b-values led to higher Dslow and Dfast measurements. The dependence of PF, Dslow, and Dfast on...
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    27
    References
    13
    Citations
    NaN
    KQI
    []