Concordance in detecting amyloid positivity between 18F-florbetaben and 18F-flutemetamol amyloid PET using quantitative and qualitative assessments.

2020 
We aimed to quantitatively and qualitatively assess whether there is a discrepancy in detecting amyloid beta (Aβ) positivity between 18F-florbetaben (FBB) and 18F-flutemetamol (FMM) positron emission tomography (PET). We obtained paired FBB and FMM PET images from 107 participants. Three experts visually quantified the Aβ deposition as positive or negative. Quantitative assessment was performed using global cortical standardized uptake value ratio (SUVR) with the whole cerebellum as the reference region. Inter-rater agreement was excellent for FBB and FMM. The concordance rates between FBB and FMM were 94.4% (101/107) for visual assessment and 98.1% (105/107) for SUVR cut-off categorization. Both FBB and FMM showed high agreement rates between visual assessment and SUVR positive or negative categorization (93.5% in FBB and 91.2% in FMM). When the two ligands were compared based on SUVR cut-off categorization as standard of truth, although not statistically significant, the false-positive rate was higher in FMM (9.1%) than in FBB (1.8%) (p = 0.13). Our findings suggested that both FBB and FMM had excellent agreement when used to quantitatively and qualitatively evaluate Aβ deposits, thus, combining amyloid PET data associated with the use of different ligands from multi-centers is feasible.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    29
    References
    7
    Citations
    NaN
    KQI
    []